TERMINAL TYPE AND QUANTITY | 11 THREADED STUD |
WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL AND |
| 220.00 AC VOLTS NOMINAL AND |
| 230.00 AC VOLTS NOMINAL AND |
| 240.00 AC VOLTS NOMINAL AND |
| 460.00 AC VOLTS NOMINAL AND |
| 480.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| 48.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
WINDING POWER RATING | 50.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
FREQUENCY RATING | 47.5 HERTZ MINIMUM AND |
| 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | FLANGE AND |
| SLOT SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.313 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 3.125 INCHES MAXIMUM |
BODY HEIGHT | 3.000 INCHES MAXIMUM |
BODY WIDTH | 3.125 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TEST DATA DOCUMENT | 08440-510-0423 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |