5950-00-230-7926 TRANSFORMER,POWER Index 5935-00-230-7929 CONNECTOR,PLUG,ELECTRICAL

National Stock Number:
5950-00-230-7928

Federal Supply Class:
5950

National Item Identification Number:
002307928

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
427226-0507690BAE SYSTEMS CONTROLS INC
5T65604620RAYCO ELECTRONIC MANUFACTURING, INC.
C1041T509349MAGNETIC CIRCUIT ELEMENTS INC


Techincal Specification:
BODY HEIGHT1.310 INCHES NOMINAL
BODY LENGTH1.500 INCHES NOMINAL
BODY WIDTH1.380 INCHES NOMINAL
CRITICALITY CODE JUSTIFICATIONFEAT
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT315.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE20.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY8 PIN
THREAD SERIES DESIGNATORUNC SINGLE GROUP
THREAD QUANTITY PER INCH32 SINGLE GROUP


Click here to Register for Free 30-day Trial