4730-00-324-0324 STRAINER ELEMENT,SEDIMENT Index 5985-00-324-0331 SWITCH,RADIO FREQUENCY TRANSMISS

National Stock Number:
5950-00-324-0325

Federal Supply Class:
5950

National Item Identification Number:
003240325

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1324295266OECO, LLC
86094611783NY-GLASS PLASTICS INC
977205254A M I/ COAST MAGNETICS INC.
977234775PIEDMONT METAL FABRICATORS INC
984718-1B82577RAYTHEON COMPANY
86094682577RAYTHEON COMPANY
PEI 948813483PRECISION ELECTRONICS, INC
C1725172149ELECTRONIC TRANSFORMER CORP


Techincal Specification:
BODY LENGTH0.800 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.530 INCHES MAXIMUM
FREQUENCY RATING15.0 KILOHERTZ NOMINAL SINGLE COMPONENT
MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT250.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE25.42 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE4.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE4.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE4.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE4.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
PROPRIETARY CHARACTERISTICSPACS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
TERMINAL TYPE AND QUANTITY30 TAB, SOLDER LUG