5960-00-583-0189 RETAINER,ELECTRON TUBE Index 5910-00-583-0194 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5950-00-583-0193

Federal Supply Class:
5950

National Item Identification Number:
005830193

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
7403470P303538LOCKHEED MARTIN CORPORATION
7403470P324446GENERAL ELECTRIC COMPANY
M7403470P324446GENERAL ELECTRIC COMPANY
M7403470P324454GENERAL ELECTRIC CO ELECTRONIC COMPONENTS DIVISION OF ELECTRONIC ATOMIC AND DEFENSE SYSTEMS GROUP
S1202258474SUPERIOR ELECTRIC HOLDING GROUP LLC


Techincal Specification:
BODY HEIGHT6.875 INCHES NOMINAL
BODY LENGTH12.750 INCHES NOMINAL
BODY WIDTH7.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH8.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL LENGTH12.750 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODFLANGE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT
WINDING OPERATING CURRENT7.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE0.00 AC VOLTS MINIMUM AND 135.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING1.0 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY3 THREADED STUD