Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1130755196SORA POWER INC.
1342495266OECO, LLC
86128582577RAYTHEON COMPANY
984768-1B82577RAYTHEON COMPANY


Techincal Specification:
BODY LENGTH1.640 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.020 INCHES NOMINAL
FREQUENCY RATING25.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
SPECIAL FEATURES1 PRIMARY,7 SECONDARIES; ALL CURRENTS ARE STATED AS RECTIFIED
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT100.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 7 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT20.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT20.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT20.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE190.89 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE13.82 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE13.82 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE13.82 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE7.78 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING SHIELDING METHODINTERNALLY SHIELDED AND BROUGHT OUT TO PRIMARY TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY22 TURRET