TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK |
RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING |
WINDING QUANTITY | 2 SINGLE COMPONENT |
INCLOSURE TYPE | HERMETICALLY SEALED |
WINDING OPERATING CURRENT | 1.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT ALL WINDING |
INDUCTANCE RATING | 45.00 MILLIHENRIES NOMINAL SINGLE COMPONENT 1ST WINDING |
| 1.75 HENRY NOMINAL SINGLE COMPONENT 2ND WINDING |
FREQUENCY RATING | 5.0 HERTZ MINIMUM AND |
| 500.0 HERTZ MAXIMUM SINGLE COMPONENT |
INDUCTANCE TYPE | FIXED |
MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
BODY LENGTH | 0.656 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 1.015 INCHES MAXIMUM |
OVERALL DIAMETER | 1.265 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
MAXIMUM OPERATING TEMP | 100.0 DEG CELSIUS |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 13499 |
DESIGN CONTROL REFERENCE | 678-1068-00 |