5950-00-681-7247 TRANSFORMER,POWER Index 5950-00-681-7254 TRANSFORMER,POWER

National Stock Number:
5950-00-681-7250

Federal Supply Class:
5950

National Item Identification Number:
006817250

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
5195415280NORTHROP GRUMMAN SYSTEMS CORPORATION DIV ES DEFENSIVE SYSTEMS DIVISION
5195420418DRS SUSTAINMENT SYSTEMS, INC. USE CAGE CODE 98255 FOR CATALOGING
5195426916NORTHROP GRUMMAN SYSTEMS CORPORATION
5195456540ASSOCIATED AIRCRAFT MANUFACTURING & SALES, INC.


Techincal Specification:
TERMINAL TYPE AND QUANTITY14 TURRET
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
50.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT2.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
2.54 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
3.02 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
1.2 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING10.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
16.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
19.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
60.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING205.0 VOLT-AMPERE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
5 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH3.563 INCHES MAXIMUM
BODY WIDTH3.063 INCHES MAXIMUM
OVERALL HEIGHT4.313 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING; FIVE SECONDARY WINDINGS,WITH FOURTH AND FIFTH WINDING CENTER TAPPED
MAXIMUM OPERATING TEMP105.0 DEG CELSIUS