5905-00-728-3450 RESISTOR,FIXED,WIRE WOUND Index 5950-00-728-3456 TRANSFORMER,POWER

National Stock Number:
5950-00-728-3451

Federal Supply Class:
5950

National Item Identification Number:
007283451

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1141753854MAGNESPEC INC


Techincal Specification:
BODY LENGTH9.000 INCHES NOMINAL
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE390.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY OR 266.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY OR 310.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY OR 350.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH8.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
MOUNTING METHODFLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
INCLOSURE TYPEPARTIALLY INCLOSED, HALF SHELL
BODY WIDTH5.500 INCHES NOMINAL
BODY HEIGHT6.500 INCHES NOMINAL
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY15 SOLDER STUD
MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL SINGLE GROUP
FREQUENCY RATING50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING OPERATING CURRENT210.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT10.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT350.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
MOUNTING FACILITY QUANTITY4 SINGLE GROUP