Description:
TRANSFORMER,POWER AUTOTRANSFORME

Detail:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.


Manufacturer Information:
4208522558COAST/ADVANCED CHIP MAGNETICS, INC.
450-1140-00058019MAGNATRONIX CORPORATION
C963272149ELECTRONIC TRANSFORMER CORP
828-22276095MAGNETIC WINDINGS COMPANY INC
6623A76301THE BOEING COMPANY
6623A95266OECO, LLC
PEI 748113483PRECISION ELECTRONICS, INC


Techincal Specification:
BODY HEIGHT2.100 INCHES NOMINAL
BODY LENGTH2.464 INCHES NOMINAL
BODY WIDTH2.136 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.960 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.213 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
WINDING OPERATING CURRENT15.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING CURRENT2.7 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT
WINDING OPERATING VOLTAGE28.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING POWER RATING75.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT
TERMINAL TYPE AND QUANTITY1 TERMINAL BLOCK W/SCREWS