TERMINAL TYPE AND QUANTITY | 7 STANDOFF, THREADED STUD |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL AND |
| 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| 6.30 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.687 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | HERMETICALLY SEALED |
BODY LENGTH | 2.187 INCHES MINIMUM AND |
| 2.312 INCHES MAXIMUM |
BODY HEIGHT | 3.125 INCHES NOMINAL |
BODY WIDTH | 2.062 INCHES NOMINAL |
MAXIMUM OPERATING TEMP | 135.0 DEG CELSIUS |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 05869 |
DESIGN CONTROL REFERENCE | 722801-34 |