TERMINAL TYPE AND QUANTITY | 8 PIN |
WINDING OPERATING VOLTAGE | 6.36 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
PRIMARY TO SECONDARY TURN RATIO | 12 TO 1 TO 6 TO 6 SINGLE COMPONENT |
PULSE REPETITION RATE | 300.0 HERTZ SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 1 SECONDARY AND |
| 2 TERTIARY SINGLE COMPONENT |
MOUNTING METHOD | TERMINAL SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.398 INCHES MINIMUM AND |
| 0.402 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.398 INCHES MINIMUM AND |
| 0.402 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY HEIGHT | 0.500 INCHES MINIMUM AND |
| 0.520 INCHES MAXIMUM |
OVERALL LENGTH | 0.558 INCHES MINIMUM AND |
| 0.562 INCHES MAXIMUM |
OVERALL WIDTH | 0.558 INCHES MINIMUM AND |
| 0.562 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TEST DATA DOCUMENT | 87557-85101 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |