5950-00-862-0001 TRANSFORMER,POWER Index 5950-00-862-0003 TRANSFORMER,POWER

National Stock Number:
5950-00-862-0002

Federal Supply Class:
5950

National Item Identification Number:
008620002

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1052591019200US ARMY ARDEC RDECOM


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FEATURES PROVIDEDSPECIAL MARKING
FREQUENCY RATING400.0 HERTZ NOMINAL ALL COMPONENTS
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTWO PHASE TO TWO PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
OVERALL HEIGHT2.625 INCHES NOMINAL
OVERALL LENGTH3.900 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURES10000 FT MAX ALTITUDE
TERMINAL TYPE AND QUANTITY17 SOLDER STUD
THREAD QUANTITY PER INCH32 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.7 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT640.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT770.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT960.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 5TH SECONDARY
WINDING OPERATING CURRENT500.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST PRIMARY INPUT
WINDING OPERATING VOLTAGE20.60 AC VOLTS NOMINAL SINGLE COMPONENT 5TH SECONDARY
WINDING OPERATING VOLTAGE208.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY INPUT
WINDING OPERATING VOLTAGE24.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE15.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING SHIELDING METHODCORE GROUNDED AND BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS