5940-00-866-1105 TERMINAL,STUD Index 5950-00-866-1108 COIL,RADIO FREQUENCY

National Stock Number:
5950-00-866-1106

Federal Supply Class:
5950

National Item Identification Number:
008661106

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
06201-800911LQK8KEYSIGHT TECHNOLOGIES, INC.
06201-8009128480HEWLETT-PACKARD COMPANY
9100-18171LQK8KEYSIGHT TECHNOLOGIES, INC.
9100-181728480HEWLETT-PACKARD COMPANY
9100-18177ZXR5KEYSIGHT TECHNOLOGIES INC
06201-800917ZXR5KEYSIGHT TECHNOLOGIES INC


Techincal Specification:
BODY HEIGHT1.734 INCHES NOMINAL
BODY LENGTH3.359 INCHES NOMINAL
BODY WIDTH2.890 INCHES NOMINAL
DISTANCE BETWEEN MOUNTING FACILITY CENTERS2.813 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODSLOT SINGLE GROUP
MOUNTING SLOT WIDTH0.219 INCHES NOMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY14 SOLDER STUD
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.6 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT12.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE102.00 AC VOLTS MINIMUM AND 125.00 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE204.00 AC VOLTS MINIMUM AND 250.00 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING VOLTAGE21.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE25.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE27.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT