| TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
| WINDING OPERATING CURRENT | 3.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| IMPEDANCE RATING IN OHMS | 600.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| 3.2 NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| FREQUENCY RATING | 100.0 HERTZ MINIMUM AND |
| 100.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| MAXIMUM TRANSFORMER POWER RATING | 50.0 MILLIWATTS SINGLE COMPONENT |
| PRIMARY TO SECONDARY TURN RATIO | 1 TO 13-6/10 SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
| MOUNTING METHOD | TERMINAL SINGLE GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 0.410 INCHES MAXIMUM |
| BODY HEIGHT | 0.475 INCHES MAXIMUM |
| BODY WIDTH | 0.310 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TEST DATA DOCUMENT | 07690-417137 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| TRANSFORMER FUNCTION | LINE |
| MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |