4130-00-928-2635 RETAINER ASSEMBLY,FILTER Index 5365-00-928-2638 BUSHING,NONMETALLIC

National Stock Number:
5950-00-928-2637

Federal Supply Class:
5950

National Item Identification Number:
009282637

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
50-0375-05318284DONGAN ELECTRIC MANUFACTURING COMPANY
53-3718284DONGAN ELECTRIC MANUFACTURING COMPANY


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING375.0 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODSLOT SINGLE GROUP
MOUNTING SLOT WIDTH0.203 INCHES NOMINAL SINGLE GROUP
OVERALL HEIGHT3.750 INCHES NOMINAL
OVERALL LENGTH5.250 INCHES NOMINAL
OVERALL WIDTH4.500 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY6 TAB W/SCREW
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT3.1 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE110.00 AC VOLTS MINIMUM AND 120.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE220.00 AC VOLTS MINIMUM AND 240.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY