CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.531 INCHES MINIMUM AND 5.593 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.625 INCHES MINIMUM AND 5.875 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
INCLOSURE TYPE | OPEN |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
OVERALL HEIGHT | 9.500 INCHES MAXIMUM |
OVERALL LENGTH | 7.000 INCHES MAXIMUM |
OVERALL WIDTH | 6.875 INCHES MAXIMUM |
MAXIMUM OPERATING TEMP | 105.0 CELSIUS |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING SLOT WIDTH | 0.438 INCHES NOMINAL SINGLE GROUP |
MOUNTING METHOD | BRACKET AND SLOT SINGLE GROUP |
RELIABILITY INDICATOR | NOT ESTABLISHED |
WINDING OPERATING CURRENT | 10.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 16.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING CURRENT | 7.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 118.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 225.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
WINDING POWER RATING | 1.7 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
TERMINAL TYPE AND QUANTITY | 1 TERMINAL BLOCK W/SCREWS |