5950-00-946-2597 TRANSFORMER,AUDIO FREQUENCY Index 6130-00-946-2599 RECTIFIER ASSEMBLY,METALLIC

National Stock Number:
5950-00-946-2598

Federal Supply Class:
5950

National Item Identification Number:
009462598

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
63A3D2210001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
BUWEPSDWG63A3D2202387NAVAL AIR WARFARE CENTER AIRCRAFT DIV


Techincal Specification:
BODY HEIGHT3.625 INCHES MINIMUM AND 3.812 INCHES MAXIMUM
BODY LENGTH2.625 INCHES MINIMUM AND 2.750 INCHES MAXIMUM
BODY WIDTH2.250 INCHES MINIMUM AND 2.375 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
WINDING OPERATING CURRENT1.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE21.80 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY7 SOLDER STUD
TEST DATA DOCUMENT10001-63A3D22 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
THREAD SERIES DESIGNATORUNC SINGLE GROUP
THREAD QUANTITY PER INCH32 SINGLE GROUP
TRANSFORMER WINDING CONNECTION TYPEWYE-DELTA