4120-00-951-9697 AIR CONDITIONER Index 5930-00-951-9700 SWITCH,TOGGLE

National Stock Number:
5950-00-951-9699

Federal Supply Class:
5950

National Item Identification Number:
009519699

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
55-194661P05502295GENERAL ELECTRIC CO GENERAL PURPOSE CONTROL DEPT
55-194661P05502989GENERAL ELECTRIC CO GE DRIVE SYSTEMS GOVERNMENT BUSINESS OPN
9T55Y44G103512GENERAL ELECTRIC CO SPECIALTY TRANSFORMER DEPT
9T58B4403512GENERAL ELECTRIC CO SPECIALTY TRANSFORMER DEPT


Techincal Specification:
BODY HEIGHT3.625 INCHES NOMINAL
BODY LENGTH4.000 INCHES NOMINAL
BODY WIDTH4.125 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.223 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT870.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE230.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING VOLTAGE460.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
TERMINAL TYPE AND QUANTITY6 SCREW


Click here to Register for Free 30-day Trial