| TERMINAL TYPE AND QUANTITY | 30 WIRE LEAD |
| WINDING OPERATING VOLTAGE | 9.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 9.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 24.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 85.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING CURRENT | 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| 14.5 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| MAXIMUM TRANSFORMER POWER RATING | 1.3 KILOVOLT-AMPERE SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 4 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 10.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 8.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | OPEN |
| BODY LENGTH | 14.500 INCHES NOMINAL |
| BODY HEIGHT | 8.000 INCHES NOMINAL |
| BODY WIDTH | 10.750 INCHES NOMINAL |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 12867 |
| DESIGN CONTROL REFERENCE | T0248 |