5950-01-044-2400 TRANSFORMER,POWER Index 5915-01-044-2403 SUPPRESSOR,PARASITIC

National Stock Number:
5950-01-044-2401

Federal Supply Class:
5950

National Item Identification Number:
010442401

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1342390095INRCORE, LLC
75516003-11K426MOOG INC.
T-20651L8V1MAGNETIKA INC
T-206553342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
75516003-186197CLIFTON PRECISION DIV OF LITTON SYSTEMS INC
75516003-199932MOOG INC.


Techincal Specification:
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.938 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BODY HEIGHT1.406 INCHES MAXIMUM
BODY LENGTH1.156 INCHES MAXIMUM
BODY WIDTH0.700 INCHES MAXIMUM
CRITICALITY CODE JUSTIFICATIONFEAT
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING HOLE DIAMETER0.093 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE33.60 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY5 WIRE LEAD