5950-01-122-4804 TRANSFORMER,POWER Index 5950-01-122-4807 TRANSFORMER,POWER

National Stock Number:
5950-01-122-4806

Federal Supply Class:
5950

National Item Identification Number:
011224806

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
10132762A486GNIMIKKEISTOKESKUS NCB FINLAND
1849272964ROBERT M. HADLEY COMPANY, INC.
4241822558COAST/ADVANCED CHIP MAGNETICS, INC.
86189282577RAYTHEON COMPANY
984878-1B82577RAYTHEON COMPANY
310-18003-0195266OECO, LLC
PEI 689013483PRECISION ELECTRONICS, INC
WE-321815634MAGNETIKA INC
WE-321826543WEMS ELECTRONICS TRANSFORMER GROUP


Techincal Specification:
BODY LENGTH0.800 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.690 INCHES MAXIMUM
FREQUENCY RATING10.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY13 PIN
THREAD QUANTITY PER INCH32 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT3.25 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE10.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE20.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE56.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY