5950-01-122-7261 REACTOR Index 5950-01-122-7263 REACTOR

National Stock Number:
5950-01-122-7262

Federal Supply Class:
5950

National Item Identification Number:
011227262

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
18524-272964ROBERT M. HADLEY COMPANY, INC.
315-18029-0195266OECO, LLC
WE-3212-215634MAGNETIKA INC
WE-3212-226543WEMS ELECTRONICS TRANSFORMER GROUP
861884-282577RAYTHEON COMPANY
986255-2B82577RAYTHEON COMPANY


Techincal Specification:
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY1 SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
WINDING OPERATING CURRENT12.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS0.023 SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING70.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING20.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INDUCTANCE TYPEFIXED
MOUNTING METHODBRACKET AND
UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.143 INCHES MINIMUM AND
0.148 INCHES MAXIMUM SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH0.906 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.718 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BODY LENGTH1.180 INCHES MAXIMUM
BODY HEIGHT1.040 INCHES MAXIMUM
BODY WIDTH1.060 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED