5999-01-129-4314 CONTACT,ELECTRICAL Index 5915-01-129-4316 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5950-01-129-4315

Federal Supply Class:
5950

National Item Identification Number:
011294315

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
4071033-0110109POWER PARAGON INC


Techincal Specification:
BODY HEIGHT1.800 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.800 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.300 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
DC RESISTANCE RATING IN OHMS0.100 SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING1.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING50.00 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING
INDUCTANCE TYPESWINGING
OVERALL HEIGHT2.300 INCHES MAXIMUM
OVERALL LENGTH2.800 INCHES MAXIMUM
OVERALL WIDTH2.050 INCHES MAXIMUM
MAXIMUM OPERATING TEMP125.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODFLANGE AND THREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.132 INCHES SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING QUANTITY1 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG
THREAD SERIES DESIGNATORUNC SINGLE GROUP
THREAD QUANTITY PER INCH32 SINGLE GROUP


Click here to Register for Free 30-day Trial