5950-01-145-2493 TRANSFORMER,POWER Index 6230-01-145-2495 FLOODLIGHT ASSEMBLY

National Stock Number:
5950-01-145-2494

Federal Supply Class:
5950

National Item Identification Number:
011452494

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
10132845A486GNIMIKKEISTOKESKUS NCB FINLAND
544051181KEYTRONICS, INC.
S93A26522B G LABORATORIES INC.
K544051181KEYTRONICS, INC.
7109054-00193322GE AVIATION SYSTEMS LLC DBA GE AVIATION
R104120A98330OECO, LLC


Techincal Specification:
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING57.0 WATTS SINGLE COMPONENT
SPECIAL FEATURES1 PRIMARY WINDING; 6 SECONDARY WINDINGS; RECTIFIED CURRENT RATINGS GIVEN
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.5 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT7.7 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT788.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT852.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE13.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE32.70 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE27.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE7.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING56.3 WATTS SINGLE COMPONENT 4TH SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING POWER RATING0.1 WATTS SINGLE COMPONENT ALL TERTIARY
WINDING POWER RATING0.2 WATTS SINGLE COMPONENT 5TH WINDING
WINDING POWER RATING22.0 WATTS SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING27.9 WATTS SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING33.3 WATTS SINGLE COMPONENT 3RD SECONDARY
TRANSFORMER WINDING CONNECTION TYPEWYE-DELTA