GENERAL CHARACTERISTICS ITEM DESCRIPTION | PARTS SHALL MEET THE REQUIREMENTS OF MIL-T-21038, GRADE 5, CLASS S, LIFE X UNLESS OTHERWISE SPECIFIED ON DRAWING |
PART NAME ASSIGNED BY CONTROLLING AGENCY | TRANSFORMER, PULSE |
SPECIAL TEST FEATURES | TURNS RATIO: 1:1; PRIMARY SINE WAVE OCL MH MINIMUM: 0.6; PRIMARY ET-CONSTANT: 1000 (V MINIMUM); RISE TIME (N5 MAX): 20; PRI/SEC CW/H (PF MAXIMUM): 65; PRI/SEC LEAKAGE INDUCTANCE (AAH MAXIMUM): 3.0; PRIMARY DCR (OHMS MAXIMUM): 0.15; SECONDARY DCR: .016 OHMS MAXIMUM |
SPECIAL FEATURES | PULSE TRANSFORMER IS DESIGNED FOR INTERMEDIATE PULSE LEVELS OF 100 TO 2,000 VOLTS AND WITH DC WINDING INSULATIONS SUITABLE FOR COUPLING BETWEEN CIRCUITS OF HIGH POTENTIAL DIFFERENCE |
SUPPLEMENTARY FEATURES | RATINGS: PEAK POWER: 25KW; AVERAGE POWER: 25 WATTS; PEAK PULSE VOLTAGE: 2KV; DC ISOLATION PRIMARY TO SECONDARY SHALL BE 5KV MINIMUM; PARTS SHALL WITHSTAND THE FOLLOWING HIGH POTENTIAL TEST WITHOUT ELECTRICAL DAMAGE, ARCING OR FLASHOVER: SECONDARY TO PRIMARY AND CORE: 15KVDC MINIMUM; PRIMARY TO CORE: 5KVDC MINIMUM; SECONDARY TO SECONDARY: 5KVDC MINIMUM; INSULATION RESISTANCE SHALL BE 10,000 MEGOHMS MINIMUM |