5950-01-169-7848 REACTOR Index 5950-01-169-7850 REACTOR

National Stock Number:
5950-01-169-7849

Federal Supply Class:
5950

National Item Identification Number:
011697849

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
279S014-728455HEVI DUTY ELECTRIC SOLA BASIC INDUSTRIES INC DIV A UNIT OF GENERAL SIGNAL CORP
279S014-751435EMS DEVELOPMENT CORPORATION
279S014-782858NWL, INC.
279S014-794324TECH-TRAN CORPORATION


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH10.468 INCHES MINIMUM AND 10.532 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH8.218 INCHES MINIMUM AND 8.282 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRITICALITY CODE JUSTIFICATIONFEAT
DC RESISTANCE RATING IN OHMS0.014 SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEOPEN
INDUCTANCE TYPESWINGING
INDUCTANCE RATING6.10 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING
OVERALL HEIGHT13.600 INCHES MINIMUM AND 13.660 INCHES MAXIMUM
OVERALL LENGTH13.500 INCHES MAXIMUM
OVERALL WIDTH10.500 INCHES MAXIMUM
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.592 INCHES MINIMUM AND 0.599 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESWEAPONS SYSTEM ESSENTIAL
WINDING OPERATING CURRENT101.5 AMPERES DC MINIMUM AND 145.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY1 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG