5950-01-169-7972 TRANSFORMER,POWER Index 5950-01-169-7974 TRANSFORMER,POWER

National Stock Number:
5950-01-169-7973

Federal Supply Class:
5950

National Item Identification Number:
011697973

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
5013606-004K1182THALES UK LIMITED DBA THALES UK LTDTRAINING AND SIMULATION
9100-06761LQK8KEYSIGHT TECHNOLOGIES, INC.
9100-067628480HEWLETT-PACKARD COMPANY
9100-06767ZXR5KEYSIGHT TECHNOLOGIES INC


Techincal Specification:
BODY HEIGHT3.150 INCHES NOMINAL
BODY LENGTH2.750 INCHES NOMINAL
BODY WIDTH2.250 INCHES NOMINAL
FREQUENCY RATING48.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTERMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT100.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT650.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE100.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING CURRENT80.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE140.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE220.00 AC VOLTS NOMINAL AND 240.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE24.20 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE25.50 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE4.50 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING16.6 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING2.4 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING POWER RATING0.9 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING11.2 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY15 WIRE LEAD