1560-01-182-1699 DOOR,ACCESS,AIRCRAFT Index 5950-01-182-1701 REACTOR

National Stock Number:
5950-01-182-1700

Federal Supply Class:
5950

National Item Identification Number:
011821700

Description:
TRANSFORMER,POWER AUTOTRANSFORME

Detail:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.


Manufacturer Information:
4072099-0110109POWER PARAGON INC
C1656172149ELECTRONIC TRANSFORMER CORP


Techincal Specification:
BODY HEIGHT2.120 INCHES NOMINAL
BODY LENGTH3.330 INCHES NOMINAL
BODY WIDTH2.510 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.810 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.510 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP160.0 FAHRENHEIT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.169 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODBRACKET AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY5 THREADED STUD
WINDING FUNCTION AND QUANTITY1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
WINDING OPERATING CURRENT280.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT
WINDING OPERATING CURRENT6.6 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING VOLTAGE230.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT
WINDING OPERATING VOLTAGE3.00 AC VOLTS NOMINAL AND 9.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING SHIELDING METHODCORE GROUNDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT


Click here to Register for Free 30-day Trial