5950-01-190-5321 TRANSFORMER,POWER Index 6220-01-190-5324 STOP LIGHT-TAILLIGHT,VEHICULAR

National Stock Number:
5950-01-190-5322

Federal Supply Class:
5950

National Item Identification Number:
011905322

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
325325-137695RAYTHEON COMPANY
C1312872149ELECTRONIC TRANSFORMER CORP
MT-383537695RAYTHEON COMPANY


Techincal Specification:
BODY LENGTH0.630 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.320 INCHES MAXIMUM
FREQUENCY RATING25.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY15 PIN
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT14.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT75.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT750.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE12.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE100.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE3.00 AC VOLTS NOMINAL AND 33.00 AC VOLTS NOMINAL AND 36.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING1.4 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING2.7 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING26.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE7.00 AC VOLTS NOMINAL AND 19.00 AC VOLTS NOMINAL AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING9.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY


Click here to Register for Free 30-day Trial