5950-01-192-4276 TRANSFORMER,POWER Index 5950-01-192-4278 TRANSFORMER,POWER

National Stock Number:
5950-01-192-4277

Federal Supply Class:
5950

National Item Identification Number:
011924277

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
TTI-1202896253TRANSFORMER TECHNICIANS INC


Techincal Specification:
BODY WIDTH2.313 INCHES MINIMUM AND 2.437 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.734 INCHES MINIMUM AND 1.766 INCHES MAXIMUM 2ND MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.922 INCHES MINIMUM AND 0.954 INCHES MAXIMUM 2ND MOUNTING FACILITY SINGLE CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.734 INCHES MINIMUM AND 1.766 INCHES MAXIMUM 1ST MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT1.600 INCHES MAXIMUM
OVERALL LENGTH2.813 INCHES MINIMUM AND 2.937 INCHES MAXIMUM
MOUNTING FACILITY QUANTITY2 1ST GROUP
MOUNTING FACILITY QUANTITY4 2ND GROUP
MOUNTING METHODTHREADED HOLE ALL GROUPINGS
NOMINAL THREAD SIZE0.112 INCHES ALL GROUPINGS
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESDC CURRENTS HAVE BEEN RECTIFIED
WINDING OPERATING CURRENT125.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.5 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE105.00 AC VOLTS MINIMUM AND 125.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE16.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE35.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY8 TAB, SOLDER LUG
THREAD SERIES DESIGNATORUNC ALL GROUPINGS