5950-01-229-2573 TRANSFORMER,POWER Index 5950-01-229-2575 TRANSFORMER,AUDIO FREQUENCY

National Stock Number:
5950-01-229-2574

Federal Supply Class:
5950

National Item Identification Number:
012292574

Description:
TRANSFORMER,AUDIO FREQUENCY

Detail:
A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.


Manufacturer Information:
651210F99149-011PQF4CAE USA INC.
M27/103-1181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M27/103/1181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-17/10381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-27/10381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-T-27/10381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY LENGTH0.406 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.350 INCHES MAXIMUM
FREQUENCY RATING400.0 HERTZ MINIMUM AND 100.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
IMPEDANCE RATING IN OHMS50.0 MINIMUM AND 60.0 MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
IMPEDANCE RATING IN OHMS500.0 MINIMUM AND 600.0 MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
INCLOSURE TYPEFULLY INCLOSED
MAXIMUM OPERATING TEMP105.0 CELSIUS
MAXIMUM TRANSFORMER POWER RATING1.0 MILLIWATTS SINGLE COMPONENT
MOUNTING METHODTERMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIFICATION/STANDARD DATA81349-MIL-PRF-17/103 GOVERNMENT SPECIFICATION
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT3.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY6 WIRE LEAD
TEST DATA DOCUMENT81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).