5950-01-230-9621 TRANSFORMER,AUDIO FREQUENCY Index 5945-01-230-9623 RELAY,SOLID STATE

National Stock Number:
5950-01-230-9622

Federal Supply Class:
5950

National Item Identification Number:
012309622

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1362153854MAGNESPEC INC
4262522558COAST/ADVANCED CHIP MAGNETICS, INC.
732519-105869RAYTHEON COMPANY


Techincal Specification:
BODY LENGTH1.120 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.920 INCHES MAXIMUM
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING2.2 WATTS SINGLE COMPONENT
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING HOLE DIAMETER0.164 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT8.4 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE14.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE27.20 AC VOLTS NOMINAL AND 30.00 AC VOLTS NOMINAL AND 33.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY12 TURRET
TEST DATA DOCUMENT05869-732519 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Click here to Register for Free 30-day Trial