5930-01-254-2150 SWITCH,PUSH Index 5950-01-254-2152 REACTOR

National Stock Number:
5950-01-254-2151

Federal Supply Class:
5950

National Item Identification Number:
012542151

Description:
TRANSFORMER ASSEMBLY

Detail:
TWO OR MORE SEPARABLE TRANSFORMER (AS MODIFIED) ON A COMMON MOUNTING OR MOUNTED ON EACH OTHER.


Manufacturer Information:
1202055196SORA POWER INC.
321-18050-0395266OECO, LLC
984882-4B82577RAYTHEON COMPANY


Techincal Specification:
DISTANCE BETWEEN MOUNTING FACILITY CENTERS4.218 INCHES NOMINAL SECOND MOUNTING FACILITY SINGLE CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS4.500 INCHES NOMINAL THIRD MOUNTING FACILITY SINGLE CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS5.375 INCHES NOMINAL FIRST MOUNTING FACILITY SINGLE CENTER GROUP
BODY HEIGHT3.570 INCHES NOMINAL
BODY LENGTH4.750 INCHES NOMINAL
BODY WIDTH2.812 INCHES NOMINAL
FREQUENCY RATING10.0 KILOHERTZ NOMINAL ALL COMPONENTS
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
MOUNTING FACILITY QUANTITY2 ALL GROUPINGS
MOUNTING HOLE DIAMETER0.187 INCHES NOMINAL FIRST GROUP
MOUNTING METHODSLOT THIRD GROUP
MOUNTING METHODTHREADED HOLE(S) SECOND GROUP
MOUNTING METHODUNTHREADED HOLE(S) FIRST GROUP
MOUNTING SLOT WIDTH0.187 INCHES NOMINAL THIRD GROUP
NOMINAL THREAD SIZE0.164 INCHES SECOND GROUP
RATING METHODELECTRICAL ALL COMPONENTS ALL PRIMARY
RATING METHODELECTRICAL ALL COMPONENTS ALL SECONDARY
RELIABILITY INDICATORNOT ESTABLISHED
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) SECOND GROUP
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SECOND COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY THIRD COMPONENT
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 3 SECONDARY FIRST COMPONENT
WINDING OPERATING CURRENT1.2 AMPERES AC MAXIMUM THIRD COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT10.0 MILLIAMPERES AC MAXIMUM THIRD COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT3.0 AMPERES AC MAXIMUM SECOND COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT30.0 MILLIAMPERES AC MAXIMUM FIRST COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT35.0 MILLIAMPERES AC MAXIMUM THIRD COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT35.0 MILLIAMPERES AC MAXIMUM SECOND COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT50.0 MILLIAMPERES AC MAXIMUM SECOND COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT50.0 MILLIAMPERES AC MAXIMUM SECOND COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL FIRST COMPONENT FIRST PRIMARY
WINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL FIRST COMPONENT SECOND PRIMARY
WINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL FIRST COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE14.14 AC VOLTS NOMINAL SECOND COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE149.88 AC VOLTS NOMINAL SECOND COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE15.55 AC VOLTS NOMINAL FIRST COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE15.55 AC VOLTS NOMINAL THIRD COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE16.26 AC VOLTS NOMINAL THIRD COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE178.16 AC VOLTS NOMINAL AND 195.84 AC VOLTS NOMINAL AND 213.51 AC VOLTS NOMINAL THIRD COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE70.70 AC VOLTS NOMINAL SECOND COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE530.25 AC VOLTS NOMINAL FIRST COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE6.01 AC VOLTS NOMINAL SECOND COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE6.01 AC VOLTS NOMINAL SECOND COMPONENT FOURTH SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL THIRD COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SECOND COMPONENT
TERMINAL TYPE AND QUANTITY2 CONNECTOR, RECEPTACLE