CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.235 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.265 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.247 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.277 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
INCLOSURE TYPE | FULLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
PROPRIETARY CHARACTERISTICS | PACS |
MOUNTING METHOD | BRACKET SINGLE GROUP |
OVERALL HEIGHT | 5.386 INCHES NOMINAL |
OVERALL LENGTH | 7.750 INCHES NOMINAL |
OVERALL WIDTH | 5.500 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | 1 PRIMARY WINDING; 20 SECONDARY WINDINGS |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 20 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 250.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 187.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 220.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 4.86 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING VOLTAGE | 4.86 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
WINDING OPERATING VOLTAGE | 8.33 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 8.33 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
TERMINAL TYPE AND QUANTITY | 64 TAB, SOLDER LUG AND 9 WIRE HOOK |
TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE |