5950-01-289-4510 TRANSFORMER,POWER Index 5950-01-289-4512 TRANSFORMER,POWER

National Stock Number:
5950-01-289-4511

Federal Supply Class:
5950

National Item Identification Number:
012894511

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
55-1330025-104655GENERAL DYNAMICS MISSION SYSTEMS, INC.
55-1330025-111293GTE GOVERNMENT SYSTEMS CORP STRATEGIC SYSTEMS DIV
TT1293211850MAGNETIKA/EAST LTD TITAN TRANSFORMER DIV


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT1.860 INCHES NOMINAL
OVERALL LENGTH1.860 INCHES NOMINAL
OVERALL WIDTH1.500 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODBRACKET SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT1.2 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT7.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT5.8 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE21.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE70.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE74.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE74.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
TERMINAL TYPE AND QUANTITY9 TURRET
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial