5950-01-293-1089 TRANSFORMER,POWER Index 5985-01-293-1091 ADAPTER,WAVEGUIDE

National Stock Number:
5950-01-293-1090

Federal Supply Class:
5950

National Item Identification Number:
012931090

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
3033A272149ELECTRONIC TRANSFORMER CORP
6097784-00153711NAVAL SEA SYSTEMS COMMAND


Techincal Specification:
BODY HEIGHT4.750 INCHES MINIMUM AND 4.938 INCHES MAXIMUM
BODY LENGTH4.563 INCHES MINIMUM AND 4.688 INCHES MAXIMUM
BODY WIDTH3.875 INCHES MINIMUM AND 4.000 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.678 INCHES MINIMUM AND 3.698 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MAXIMUM TRANSFORMER POWER RATING300.0 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.250 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.1 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT682.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
WINDING POWER RATING252.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY4 THREADED STUD
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial