5950-01-293-2045 TRANSFORMER,POWER Index 5950-01-293-2047 TRANSFORMER,POWER

National Stock Number:
5950-01-293-2046

Federal Supply Class:
5950

National Item Identification Number:
012932046

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
C32A9015-326512NORTHROP GRUMMAN SYSTEMS CORPORATION
M940800348MICROTRAN CO INC


Techincal Specification:
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.115 INCHES MINIMUM AND 1.135 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT0.866 INCHES MINIMUM AND 0.990 INCHES MAXIMUM
OVERALL LENGTH1.437 INCHES MAXIMUM
OVERALL WIDTH0.960 INCHES MINIMUM AND 0.990 INCHES MAXIMUM
MAXIMUM OPERATING TEMP105.0 CELSIUS
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODSLOT SINGLE GROUP
MOUNTING SLOT WIDTH0.110 INCHES MINIMUM AND 0.130 INCHES MAXIMUM SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT1.2 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE12.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE12.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING POWER RATING0.01 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY4 WIRE HOOK