5950-01-296-2226 TRANSFORMER,POWER Index 5950-01-296-2228 TRANSFORMER,POWER

National Stock Number:
5950-01-296-2227

Federal Supply Class:
5950

National Item Identification Number:
012962227

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
B300BTZ13JK30882MICRON INDUSTRIES CORP
B300BTZJK30882MICRON INDUSTRIES CORP


Techincal Specification:
BODY HEIGHT3.812 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEPARTIALLY INCLOSED, DOUBLE SHELL
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL LENGTH4.750 INCHES NOMINAL
OVERALL WIDTH4.500 INCHES NOMINAL
MAXIMUM OPERATING TEMP105.0 CELSIUS
MAXIMUM TRANSFORMER POWER RATING300.0 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODBRACKET AND SLOT SINGLE GROUP
MOUNTING SLOT WIDTH0.203 INCHES NOMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESPRIMARY J-2 JUMPERS AND TYPE K FUSE CLIPS MOUNTED ON SSECONDARY
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.61 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE110.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE220.00 AC VOLTS NOMINAL AND 230.00 AC VOLTS NOMINAL AND 240.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
TERMINAL TYPE AND QUANTITY2 TERMINAL BLOCK W/SCREWS