Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
48480172149ELECTRONIC TRANSFORMER CORP
9563-10048313B.C. SYSTEMS INC.


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.687 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.125 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL HEIGHT3.900 INCHES NOMINAL
OVERALL LENGTH4.625 INCHES NOMINAL
OVERALL WIDTH2.500 INCHES NOMINAL
MOUNTING FACILITY QUANTITY2 ALL GROUPINGS
MOUNTING HOLE DIAMETER0.218 INCHES MINIMUM AND 0.221 INCHES MAXIMUM 1ST GROUP
MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL 2ND GROUP
MOUNTING METHODUNTHREADED HOLE ALL GROUPINGS
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT10.0 AMPERES AC MAXIMUM SINGLE COMPONENT 5TH SECONDARY
WINDING FUNCTION AND QUANTITY3 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT0.1 AMPERES AC MAXIMUM SINGLE COMPONENT 6TH SECONDARY
WINDING OPERATING CURRENT0.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT4.4 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT4.4 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT5.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE11.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE208.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE12.50 AC VOLTS NOMINAL SINGLE COMPONENT 5TH SECONDARY
WINDING OPERATING VOLTAGE17.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE23.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE23.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE27.00 AC VOLTS NOMINAL SINGLE COMPONENT 6TH SECONDARY
TERMINAL TYPE AND QUANTITY39 TURRET