5950-01-309-9701 TRANSFORMER,POWER Index 5950-01-309-9703 TRANSFORMER,POWER

National Stock Number:
5950-01-309-9702

Federal Supply Class:
5950

National Item Identification Number:
013099702

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
11-51562-00221562GENERAL DYNAMICS OTS (AEROSPACE), INC.
11-51562-00251562POWER MAGNE-TECH CORP DBA POWER MAGNETIC
761800-221562GENERAL DYNAMICS OTS (AEROSPACE), INC.


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.550 INCHES NOMINAL SINGLE MOUNTING FACILITY 2ND CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY 2ND CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.550 INCHES NOMINAL SINGLE MOUNTING FACILITY 1ST CENTER GROUP
FEATURES PROVIDEDCOLOR CODED LEAD
FREQUENCY RATING100.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP95.0 CELSIUS
MAXIMUM TRANSFORMER POWER RATING160.0 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY2 1ST GROUP
MOUNTING FACILITY QUANTITY4 2ND GROUP
MOUNTING HOLE DIAMETER0.106 INCHES MINIMUM AND 0.114 INCHES MAXIMUM 2ND GROUP
MOUNTING METHODTHREADED HOLE 1ST GROUP
MOUNTING METHODUNTHREADED HOLE 2ND GROUP
NOMINAL THREAD SIZE0.086 INCHES 1ST GROUP
OVERALL HEIGHT1.165 INCHES MAXIMUM
OVERALL LENGTH1.770 INCHES MAXIMUM
OVERALL WIDTH1.220 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY12 WIRE LEAD
THREAD SERIES DESIGNATORUNC 1ST GROUP
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT13.4 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT70.7 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT989.9 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT530.3 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE16.26 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE56.56 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE56.56 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE37.47 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE395.92 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY