5950-01-329-6267 COIL,ELECTRICAL Index 5985-01-329-6269 ANTENNA

National Stock Number:
5950-01-329-6268

Federal Supply Class:
5950

National Item Identification Number:
013296268

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
11-00069-00221562GENERAL DYNAMICS OTS (AEROSPACE), INC.
726908-221562GENERAL DYNAMICS OTS (AEROSPACE), INC.


Techincal Specification:
BODY HEIGHT1.280 INCHES MAXIMUM
BODY LENGTH1.200 INCHES MAXIMUM
BODY WIDTH0.594 INCHES MAXIMUM
FEATURES PROVIDEDCOLOR CODED TERMINAL
FREQUENCY RATING28.5 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP134.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.100 INCHES MINIMUM AND 0.140 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESFOUR PRIMARY WINDINGS AND TWO SECONDARY WINDINGS
TERMINAL TYPE AND QUANTITY11 PIN AND 2 WIRE LEAD
TEST DATA DOCUMENT16340-11-00069 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
WINDING FUNCTION AND QUANTITY4 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.8 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT30.0 AMPERES AC NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT5.8 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE11.31 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE56.56 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE33.94 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING328.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING339.3 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY
WINDING POWER RATING95.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY