CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.940 INCHES MINIMUM AND 5.060 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.940 INCHES MINIMUM AND 5.060 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |
INCLOSURE TYPE | FULLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING METHOD | SLOT SINGLE GROUP |
MOUNTING SLOT WIDTH | 0.297 INCHES MINIMUM AND 0.327 INCHES MAXIMUM SINGLE GROUP |
OVERALL HEIGHT | 7.000 INCHES MAXIMUM |
OVERALL LENGTH | 9.500 INCHES MAXIMUM |
OVERALL WIDTH | 5.500 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
TEST DATA DOCUMENT | 03956-1808601 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 8.26 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING VOLTAGE | 90.00 AC VOLTS MINIMUM AND 150.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
WINDING POWER RATING | 1.07 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
WINDING POWER RATING | 19.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 71.70 AC VOLTS MINIMUM AND 129.50 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |