5950-01-330-3521 COIL,RADIO FREQUENCY Index 5950-01-330-3523 COIL,ELECTRICAL

National Stock Number:
5950-01-330-3522

Federal Supply Class:
5950

National Item Identification Number:
013303522

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
10132948A486GNIMIKKEISTOKESKUS NCB FINLAND
M39010/02-A4R7KS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39010/02A4R7KS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39010/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39010/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
TEST DATA DOCUMENT81349-MIL-C-39010 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
MAXIMUM OPERATING TEMP105.0 DEG CELSIUS
SPECIFICATION/STANDARD DATA81349-MIL-C-39010/2 GOVERNMENT SPECIFICATION
SPEC/STD CONTROLLING DATA
MANUFACTURERS CODE81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCEMIL-PRF-39010/2
DEFINITIVE GOVERNMENT SPEC/STD REFERENCEM39010/02A4R7KS
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
INCLOSURE TYPEFULLY INCLOSED
WINDING OPERATING CURRENT380.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS0.550 SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING4.70 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
QUALITY FACTOR44 MINIMUM SINGLE COMPONENT SINGLE WINDING
COIL FORM TYPESOLID SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
MOUNTING METHODTERMINAL SINGLE GROUP
BODY LENGTH0.390 INCHES MINIMUM AND
0.430 INCHES MAXIMUM
OVERALL DIAMETER0.152 INCHES MINIMUM AND
0.172 INCHES MAXIMUM
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001