5950-01-331-2838 COIL,RADIO FREQUENCY Index 5950-01-331-2840 TRANSFORMER,POWER

National Stock Number:
5950-01-331-2839

Federal Supply Class:
5950

National Item Identification Number:
013312839

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1929072964ROBERT M. HADLEY COMPANY, INC.
5T39304620RAYCO ELECTRONIC MANUFACTURING, INC.
841324-000106481NORTHROP GRUMMAN SYSTEMS CORPORATION
841324-000113973LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
WE414815634MAGNETIKA INC
WE414826543WEMS ELECTRONICS TRANSFORMER GROUP


Techincal Specification:
BODY HEIGHT1.040 INCHES MAXIMUM
FREQUENCY RATING25.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
OVERALL LENGTH1.030 INCHES MAXIMUM
OVERALL WIDTH1.030 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY14 PIN
TEST DATA DOCUMENT13973-841324 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT120.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE14.14 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE18.38 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE18.38 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE9.89 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE9.89 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING1.18 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING1.18 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING2.2 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING2.2 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY