CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.740 INCHES MINIMUM AND 3.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 45.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
INCLOSURE TYPE | FULLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
OVERALL HEIGHT | 3.720 INCHES MINIMUM AND 3.800 INCHES MAXIMUM |
OVERALL LENGTH | 4.470 INCHES MINIMUM AND 4.550 INCHES MAXIMUM |
OVERALL WIDTH | 3.550 INCHES MINIMUM AND 3.800 INCHES MAXIMUM |
MAXIMUM OPERATING TEMP | 155.0 CELSIUS |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING HOLE DIAMETER | 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM SINGLE GROUP |
MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
RELIABILITY INDICATOR | NOT ESTABLISHED |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 18.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 28.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING POWER RATING | 504.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
TERMINAL TYPE AND QUANTITY | 5 TAB, SOLDER LUG |
TEST DATA DOCUMENT | 13973-841354 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |