CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 7.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT AND HUMIDITY RESISTANT |
INCLOSURE TYPE | FULLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
OVERALL HEIGHT | 6.880 INCHES MAXIMUM |
OVERALL LENGTH | 15.250 INCHES MAXIMUM |
OVERALL WIDTH | 8.630 INCHES MAXIMUM |
MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
MAXIMUM TRANSFORMER POWER RATING | 5.0 KILOVOLT-AMPERE SINGLE COMPONENT |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING SLOT WIDTH | 0.440 INCHES NOMINAL SINGLE GROUP |
MOUNTING METHOD | SLOT SINGLE GROUP |
RELIABILITY INDICATOR | NOT ESTABLISHED |
WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 41.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
WINDING SHIELDING METHOD | PRIMARY AND SECONDARY SHIELDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
TEST DATA DOCUMENT | 30003-1217AS310 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |