5950-01-332-5684 REACTOR Index 5950-01-332-5686 REACTOR

National Stock Number:
5950-01-332-5685

Federal Supply Class:
5950

National Item Identification Number:
013325685

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
305137-137695RAYTHEON COMPANY
MT-395937695RAYTHEON COMPANY


Techincal Specification:
DC RESISTANCE RATING IN OHMS0.009 SINGLE COMPONENT 1ST WINDING
DC RESISTANCE RATING IN OHMS0.035 SINGLE COMPONENT 2ND WINDING
DC RESISTANCE RATING IN OHMS0.110 SINGLE COMPONENT 3RD WINDING
DC RESISTANCE RATING IN OHMS0.130 SINGLE COMPONENT 4TH WINDING
DC RESISTANCE RATING IN OHMS0.350 SINGLE COMPONENT 5TH WINDING
FREQUENCY RATING15.75 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING17.00 MICROHENRIES NOMINAL SINGLE COMPONENT 2ND WINDING
INDUCTANCE RATING17.00 MICROHENRIES NOMINAL SINGLE COMPONENT 3RD WINDING
INDUCTANCE RATING4.50 MICROHENRIES NOMINAL SINGLE COMPONENT 1ST WINDING
INDUCTANCE RATING27.00 MICROHENRIES NOMINAL SINGLE COMPONENT 4TH WINDING
INDUCTANCE RATING27.00 MICROHENRIES NOMINAL SINGLE COMPONENT 5TH WINDING
INDUCTANCE TYPEFIXED
OVERALL HEIGHT0.890 INCHES MAXIMUM
OVERALL LENGTH1.400 INCHES MAXIMUM
OVERALL WIDTH1.400 INCHES MAXIMUM
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT ALL WINDING
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESFIRST WINDING HAS SPLIT TERMINALS FOR DUAL CONNECTION
WINDING OPERATING CURRENT1.7 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND WINDING
WINDING OPERATING CURRENT200.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 5TH WINDING
WINDING OPERATING CURRENT6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST WINDING
WINDING OPERATING CURRENT500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD WINDING
WINDING OPERATING CURRENT500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH WINDING
WINDING QUANTITY5 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY12 PIN
TEST DATA DOCUMENT37695-305137 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)