BODY HEIGHT | 1.900 INCHES NOMINAL |
FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
INCLOSURE TYPE | HERMETICALLY SEALED |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
OVERALL LENGTH | 3.780 INCHES NOMINAL |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |
SPECIAL FEATURES | TRANSFORMER, P/N AA24102, IS POTTED INSIDE A TD-CAPSULE, P/N TD-120; TERMINALS (PIGTAILS) ARE 10 INCHES (MIN) IN LENGTH; YELLOW - PRIMARY; BLACK - 21V (S-1); GRAY - 21V (S-2); WHITE - 21V (S-3); GREEN - 13V (S-4), BROWN - 34V (S-5); SHIPPING WEIGHT IS 3.30 LBS |
WINDING OPERATING CURRENT | 2.2 AMPERES AC NOMINAL SINGLE COMPONENT 5TH SECONDARY |
WINDING OPERATING CURRENT | 0.5 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
WINDING OPERATING CURRENT | 0.5 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING CURRENT | 0.5 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING CURRENT | 1.2 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 13.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 21.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING VOLTAGE | 21.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING VOLTAGE | 21.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
WINDING OPERATING VOLTAGE | 34.00 AC VOLTS NOMINAL SINGLE COMPONENT 5TH SECONDARY |
WINDING POWER RATING | 130.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |