6680-00-959-9823 COUNTER Index 5360-00-959-9832 SPRING,HELICAL,COMPRESSION

National Stock Number:
5970-00-959-9827

Federal Supply Class:
5970

National Item Identification Number:
009599827

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
1961006-110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH0.900 INCHES MINIMUM AND 1.100 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG25.0 MINIMUM AND 35.0 MAXIMUM AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES0.740 INCHES MINIMUM AND 0.900 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTIONMILDEW RESISTANT AND PETROLEUM RESISTANT AND WATER RESISTANT AND HYDRAULIC FLUID
FIRST BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.030 INCHES MINIMUM AND 0.050 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY INSIDE DIAMETER0.260 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH1.640 INCHES MINIMUM AND 2.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.050 INCHES MINIMUM AND 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MATERIALRUBBER CHLOROPRENE CLASS CR LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.030 INCHES MINIMUM AND 0.050 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING-55.0 CELSIUS AND 80.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.030 INCHES MINIMUM AND 0.050 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY