DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.780 INCHES MINIMUM AND 2.180 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.980 INCHES MAXIMUM AS SUPPLIED |
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 20.0 MAXIMUM AS SUPPLIED |
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 25.0 MINIMUM AND 35.0 MAXIMUM AFTER UNRESTRICTED RECOVERY |
COLOR | BLACK |
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 10000.0 |
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 1.520 INCHES MINIMUM AND 1.860 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 1.690 INCHES MAXIMUM AS SUPPLIED |
FIRST BRANCH INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
FIRST BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
FIRST BRANCH WALL THICKNESS | 0.050 INCHES MINIMUM AND 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
FIRST BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
FLEXIBILITY | FLEXIBLE |
MAIN BODY INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
MAIN BODY INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
MAIN BODY OVERALL LENGTH | 3.300 INCHES MINIMUM AND 4.040 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
MAIN BODY OVERALL LENGTH | 4.040 INCHES MAXIMUM AS SUPPLIED |
MAIN BODY WALL THICKNESS | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
MAIN BODY WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
MATERIAL | RUBBER CHLOROPRENE CLASS CR LOCATION NOT OTHERWISE SPECIFIED |
MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SECOND BRANCH INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
SECOND BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
SECOND BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
SECOND BRANCH WALL THICKNESS | 0.050 INCHES MINIMUM AND 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
STYLE DESIGNATOR | TRANSITION-1 TO 3 CABLES |
TEMP RATING | -55.0 CELSIUS AND 80.0 CELSIUS |
THIRD BRANCH INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
THIRD BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
THIRD BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
THIRD BRANCH WALL THICKNESS | 0.050 INCHES MINIMUM AND 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |